This Acti9 Vigi iC60 is a modular add-on residual current devices. It is a 4P, rated current is 63A, operating voltage is 400VAC to 415VAC according to IEC 61009-1. The earth leakage protection class is AC type with a sensitivity of 30mA and a voltage independent technology. This product protects against short circuit, cable overload, electrical shock by indirect contact and fire hazards. A VisiTrip window is here to indicate a fault tripping by a red mechanical indicator on the front face. It can be combined with iC60 or Acti9 Reflex iC60, to provide protection of persons and protection of installations. This product complies with EN/IEC 61009-1 and EN/IEC 61009-2-1 standards. The Ue rated operational voltage is from 400VAC to 415VAC conforming to EN/IEC 61009-1 and EN/IEC 61009-2-1 standards. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The pollution degree is 3. It can be mounted on DIN rail. The width in 9mm pitches is 7. The dimensions are (W) 135mm x (H) 91mm x (D) 73.5mm. The weight is 0.245kg. The degree of protection is IP20 and IP40 in an enclosure. The operating temperature is from -5°C to +60°C. The storage temperature is from -40°C to +85°C.
Business Unit | |
---|---|
Product Family | |
Product Range |
Vigi iC60 – earth leakage add-on block – 4P – 63A – 30mA – AC type
6,077.37 جنيه مصري بدون الضريبة
This Acti9 Vigi iC60 is a modular add-on residual current devices. It is a 4P, rated current is 63A, operating voltage is 400VAC to 415VAC according to IEC 61009-1. The earth leakage protection class is AC type with a sensitivity of 30mA and a voltage independent technology. This product protects against short circuit, cable overload, electrical shock by indirect contact and fire hazards. A VisiTrip window is here to indicate a fault tripping by a red mechanical indicator on the front face. It can be combined with iC60 or Acti9 Reflex iC60, to provide protection of persons and protection of installations. This product complies with EN/IEC 61009-1 and EN/IEC 61009-2-1 standards. The Ue rated operational voltage is from 400VAC to 415VAC conforming to EN/IEC 61009-1 and EN/IEC 61009-2-1 standards. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The pollution degree is 3. It can be mounted on DIN rail. The width in 9mm pitches is 7. The dimensions are (W) 135mm x (H) 91mm x (D) 73.5mm. The weight is 0.245kg. The degree of protection is IP20 and IP40 in an enclosure. The operating temperature is from -5°C to +60°C. The storage temperature is from -40°C to +85°C.
Business Unit | |
---|---|
Product Family | |
Product Range |
منتجات ذات صلة
-
طاقة
Distribution board, Acti9 Vertical TPN, 24 ways, flush mount, 3P isolator or C120 MCB 125 A incomer provision
4,857.54 جنيه مصريالسعر الأصلي هو: 4,857.54 EGP.4,857.48 جنيه مصريالسعر الحالي هو: 4,857.48 EGP. بدون الضريبة -
طاقة
Easy9 – flush enclosure 12 modules – smoked door – with E/N term.blocks
385.53 جنيه مصري بدون الضريبة -
طاقة
Vertical metal distribution board, Easy9, 36 ways
2,289.04 جنيه مصريالسعر الأصلي هو: 2,289.04 EGP.1,551.84 جنيه مصريالسعر الحالي هو: 1,551.84 EGP. بدون الضريبة -
طاقة
Distribution board, Acti9 Vertical TPN, 36 ways, flush mount, 3P NSX 250 A incomer provision