TeSys LR97D electronic overcurrent relay, 7A/690V, to be supplied with 200-240V AC, for protection of motors with a rated current 1.2-6A. It provides 3 dials to adjust the protection, LOAD (1.2-7A) for the overcurrent level, O-TIME (0.3-10sec) for the acceptable duration of the overcurrent, D-TIME (0.5-30sec) for the starting duration. In addition, the device trips when the current is higher than 3 x LOAD during more than 0.5sec in steady state and if there is a missing phase during more than 3sec. Settings also include selectors for 1-phase/3-phase motors and manual/automatic reset, the device has a reset button, a test/stop button, 2 LED indicators (Run/Trip), 2 auxiliary contacts 1NO/NC for fault signaling. Settings can be locked by sealing the transparent cover. For direct attachment to the bottom terminals of a 3-phase contactor LC1D09-D38, with screw clamp terminals on bottom, the separate mounting from the contactor is possible using the terminal block LAD7B106 (to be ordered separately). Multi-standards certified (IEC, UL, CSA, CCC, EAC), compliant RoHs/Reach.
Electronic overcurrent relay, TeSys LR97D, 200 to 240VAC, 1.2 to 7A, 1C/O
2,155.96 جنيه مصري بدون الضريبة
TeSys LR97D electronic overcurrent relay, 7A/690V, to be supplied with 200-240V AC, for protection of motors with a rated current 1.2-6A. It provides 3 dials to adjust the protection, LOAD (1.2-7A) for the overcurrent level, O-TIME (0.3-10sec) for the acceptable duration of the overcurrent, D-TIME (0.5-30sec) for the starting duration. In addition, the device trips when the current is higher than 3 x LOAD during more than 0.5sec in steady state and if there is a missing phase during more than 3sec. Settings also include selectors for 1-phase/3-phase motors and manual/automatic reset, the device has a reset button, a test/stop button, 2 LED indicators (Run/Trip), 2 auxiliary contacts 1NO/NC for fault signaling. Settings can be locked by sealing the transparent cover. For direct attachment to the bottom terminals of a 3-phase contactor LC1D09-D38, with screw clamp terminals on bottom, the separate mounting from the contactor is possible using the terminal block LAD7B106 (to be ordered separately). Multi-standards certified (IEC, UL, CSA, CCC, EAC), compliant RoHs/Reach.
Business Unit | |
---|---|
Product Family | |
Product Range |
منتجات ذات صلة
-
طاقة
Distribution board, Acti9 Vertical TPN, 48 ways, flush mount, 3P NSX 250 A incomer provision
11,750.70 جنيه مصريالسعر الأصلي هو: 11,750.70 EGP.11,750.70 جنيه مصريالسعر الحالي هو: 11,750.70 EGP. بدون الضريبة -
طاقة
Vertical metal distribution board, Easy9, 36 ways
2,289.04 جنيه مصريالسعر الأصلي هو: 2,289.04 EGP.1,551.84 جنيه مصريالسعر الحالي هو: 1,551.84 EGP. بدون الضريبة -
طاقة
Distribution board, Acti9 Vertical TPN, 18 ways, flush mount, 3P NSX 250 A incomer provision
5,455.70 جنيه مصريالسعر الأصلي هو: 5,455.70 EGP.5,455.63 جنيه مصريالسعر الحالي هو: 5,455.63 EGP. بدون الضريبة -
طاقة
Horizontal metal distribution board, Easy9, 2 row, 24 ways
1,923.68 جنيه مصريالسعر الأصلي هو: 1,923.68 EGP.1,304.16 جنيه مصريالسعر الحالي هو: 1,304.16 EGP. بدون الضريبة